The following table shows the data outputs and protocols available for you to integrate Aeroqual products with third-party systems.
Note: Aeroqual provides documentation but no support for the integration.
Connect API | Cloud API | Digital RS232 | Digital RS485 | Analog 0-5V | Analog 4-20mA | Relay | |
---|---|---|---|---|---|---|---|
AQM 65 | ✓ | ✓ | |||||
AQS 1 | ✓ | ✓ | |||||
Dust Sentry Pro | ✓ | ✓ | |||||
Dust Sentry | ✓ | ✓ | |||||
AQY 1 | ✓ | ✓ | |||||
AQY R | ✓ | ✓ | |||||
Series 500 | ✓ | ✓ | |||||
Series 300 | ✓ | ||||||
Series 200 | |||||||
Series 900 | ✓ | ✓ | |||||
Series 930 | ✓ | ✓ | |||||
SM70 | ✓ | ✓ | ✓ | ✓ | |||
SM50 | ✓ | ✓ | ✓ | ✓ |
*Requires optional components
Note: You may need to buy a licence to activate or maintain outputs/protocols.
Cloud API
Requirements
- Active Aeroqual Cloud API licence on the Aeroqual monitor.
- API user account registered on Aeroqual Cloud.
- Internet connection.
Note: If you get error 403 when trying to use the Cloud API to retrieve data, it could because the monitor doesn’t have the API licence or it doesn’t have API access. Please contact your distributor or email support@aeroqual.com.
Features
- Data polled from Aeroqual Cloud servers. No direct monitor connection required.
- V2 API for latest functionality. New endpoints will be developed.
- Swagger repository for documentation allows for live testing of commands.
- JSON formatted responses.
Example use cases
- Live data displayed on website from network of monitors.
- Custom software to display monitor data quickly.
- Input monitor data into third-party software (eg. Eagle.IO).
- Custom formatting for data exportation.
Documentation
URL: https://api.demo.cloud.aeroqual.com/swag...
Login name: demo@aeroqual.com
Password: demo123
Connect API
Requirements
- Active Aeroqual Connect API licence on the Aeroqual monitor.
- API user account registered on Aeroqual Connect.
- LAN or VPN connection to the monitor.
Features
- Directly polls the monitor with no need to upload data to Aeroqual Cloud.
- Currently supports V1 API.
- JSON formatted responses.
Example use cases
- Live data displayed on intranet from network of monitors.
- Custom software to display monitor data quickly.
- Custom formatting for data exportation.
RS232
Requirements
- Legacy Communications licence (AQM 65 / AQS 1 / Dust Sentry Pro / Dust Sentry)
Features
- Proprietary protocol does not conform to Modbus standards etc.
- No support for Virtual or Custom Channels
- No support for Virtual Aux
- No new development
- Depreciated (AQM 65 / AQS 1 / Dust Sentry Pro / Dust Sentry)
Example use cases
- Custom formatting for data exportation.
- Direct data input into third-party software.
RS485
Requirements
None
Features
- Proprietary protocol based on industrial protocol RS485.
- No new development.
Example use cases
- Custom formatting for data exportation.
- Direct data input into third-party software.
0-5V
Requirements
- Suitable data logger or PLC
Features
- 0 to 5 V signal is a proportional signal based on the measurement.
- Only supports one measurement output.
Example use cases
- Direct data input into third-party hardware/building control systems.
4-20mA
Requirements
- Suitable data logger or PLC
Features
- 0 to 5 V signal is a proportional signal based on the measurement.
- Only supports one measurement per output.
- 1 for S900 / S930
Example use cases
- Direct data input into third-party hardware/building control systems.
Relay
Requirements
None
Features
- User-configurable set points.
- Control of third-party equipment.
Example use cases
- Maintain ozone concentration within set limits by control of ozone generator.